Tribology & Contact
Hertz Line Contact Calculator
Contact half-width, full contact width, line load and maximum Hertz pressure for cylinder–flat and parallel cylinder–cylinder contacts.
All calculations run in your browser using classical elastic Hertz theory. This is a screening calculator; it does not implement or claim compliance with ISO, AGMA, DIN or bearing-rating standards.
Inputs
Geometry and load
Materials
Results
Maximum Hertz pressure
2.033 GPa
p0 · p0 = 2F / (π b L) = 2w / (π b)
Mean contact pressure
1.596 GPa
p_mean · p_mean = F / (2bL) = π p0 / 4
Contact half-width
0.02349 mm
b · b = √(4 F R' / (π L E*))
Full contact width
0.04698 mm
2b · 2b
Effective radius
0.635 mm
R' · 1/R' = 1/R1 + 1/R2
Effective elastic modulus
109.89 GPa
E* · 1/E* = (1−ν1²)/E1 + (1−ν2²)/E2
Total normal load
75 N
F · entered
Line load
75 N/mm
w · w = F / L
Contact length
1 mm
L · entered
Subsurface shear (classical line contact)
τ_max ≈ 0.30 p0 = 609.8 MPa at depth z ≈ 0.786 b = 0.0185 mm
Maximum principal shear stress (τ1) below the centerline for frictionless plane-strain Hertz contact. It is a distinct quantity from the surface pressure p0.
Classical elastic Hertz screening values for the entered inputs. They are not a bearing or gear rating, a design allowable or an engineering recommendation.
Line Contact vs Point Contact
Line contact
- parallel cylinders or cylinder–flat
- idealised rectangular contact strip 2b × L
- contact width scales with √load
Point contact
- sphere–flat or sphere–sphere
- circular (or elliptical) contact area
- contact radius scales with load^(1/3)
Worked example
Two identical steel cylinders: R1 = R2 = 1.27 mm, L = 1.00 mm, F = 75 N, E1 = E2 = 200 GPa, ν1 = ν2 = 0.30
R' = 1.27·1.27 / 2.54 = 0.635 mm
1/E* = 2 · 0.91 / 200 GPa → E* ≈ 109.89 GPa
w = 75 N / 1 mm = 75 N/mm
b = √(4 · 75 · 0.635 / (π · 109 890)) ≈ 0.02349 mm, 2b ≈ 0.04698 mm
p0 = 2 · 75 / (π · 0.02349) ≈ 2033 MPa ≈ 2.033 GPa, p_mean ≈ 1.597 GPa
These are the calculator’s default inputs; use “Load worked example” to reproduce them.
What is Hertzian line contact?
When a cylinder is pressed against a flat, or two cylinders with parallel axes are pressed together, the undeformed bodies touch along a line. Under load the contact spreads into a narrow strip of width 2b along the contact length L. Because L is much larger than b, the problem is treated as two-dimensional (plane strain) and the load is expressed per unit length.
Effective elastic modulus
1 / E* = (1 − ν1²) / E1 + (1 − ν2²) / E2
Both bodies deform, so both compliances add. A softer partner dominates E*. This page uses the E* convention throughout; some texts use E′ = 2E*, which changes the constants in every equation — do not mix them.
Effective radius
1 / R' = 1 / R1 + 1 / R2 → R' = R1·R2 / (R1 + R2)
For two cylinders in external contact both curvatures add. For a cylinder on a flat, R2 → ∞ and R′ = R1; the flat option therefore asks only for the cylinder radius.
Contact width
b = √(4 F R' / (π L E*)) = √(4 w R' / (π E*)), w = F / L
b is the contact half-width, measured from the centerline to the edge of the strip; the full contact width is 2b. b grows with the square root of the line load.
Maximum Hertz pressure
p0 = 2F / (π b L) = 2w / (π b), p_mean = F / (2bL), p0 = 4 p_mean / π
The surfaces are deepest in each other at the centerline, so the elastic interference — and the pressure — is highest there and falls to zero at x = ±b. p0 is about 27% higher than the mean pressure.
Pressure distribution
p(x) = p0 √(1 − (x/b)²), −b ≤ x ≤ b
The pressure across the strip is semi-elliptical, not uniform. The point-contact (sphere) distribution has the same shape over a circle, but different constants — it must not be used for cylinders.
Subsurface shear stress
τ1,max ≈ 0.300 p0 at z ≈ 0.786 b
In frictionless Hertz line contact the largest principal shear stress occurs below the surface on the centerline, not at the surface. This is the classical result reported by Johnson (Contact Mechanics, 1985, §4.2); yielding or rolling-contact fatigue often initiates near this depth. Friction moves the critical point toward the surface and is not included.
Assumptions and limitations
The classical Hertz line-contact solution assumes:
- smooth surfaces
- non-conforming contact
- homogeneous, isotropic materials
- linear elasticity and small strains
- frictionless normal loading
- contact width small compared with body dimensions
- parallel cylinder axes and no significant edge effects
Real finite-length rollers can experience edge loading, with pressure peaks at the roller ends well above p0. Results are not valid for severe misalignment, crowned or profiled rollers, crossed or internal (conformal) cylinders, plastic deformation or adhesive contact; these are possible future extensions.
Engineering use cases
- rollers and cylindrical roller bearings (local contact screening)
- cylindrical cams and followers
- local gear-tooth contact approximated as two cylinders
- rolling/sliding tribological contacts, e.g. block-on-ring tests
- contact-mechanics education and preliminary engineering calculations
This simplified calculator does not replace bearing-rating or gear-rating standards. For related work, see tribology research. To normalise measured wear from a line-contact test such as block-on-ring, use the Wear Rate Calculator. For spur-gear flanks modelled as pitch-point cylinders, use the Gear Stress Calculator.
References
- K. L. Johnson, Contact Mechanics, Cambridge University Press (1985), ch. 4 — two-dimensional Hertz contact.
- H. Hertz, "Über die Berührung fester elastischer Körper", J. reine angew. Math. 92, 156–171 (1882).
- Wikipedia — Contact mechanics: contact between two cylinders with parallel axes.